Vitreo Help

How every part of Vitreo works, in short pages

\Database and Files\Sync All, Recreate Project, Recreate Database

Sync All, Recreate Project, Recreate Database

Vitreo has several tools to bring the database in line with your files. Use the smallest one that solves the problem.

Tool Where What it does Use it when
Sync all projects Projects pane, more options menu (three dots) Reads the folders of every project. Only new and changed files. You want all projects up to date, for example before a search in all projects.
Sync database Database pane > Tools Checks every file in the database against the disk. Deleted files are removed, changed files are read. Files were deleted or changed while Vitreo was closed.
Recreate project Right-click a project Deletes what Vitreo stored about this project and reads all its files again. Other projects stay. Item boxes of one project look wrong or old, or files could not be read before.
Recreate Database pane > Tools Deletes the stored data of the active project or of all projects, and reads again. The database looks wrong in many projects.
Clear Database pane > Tools Empties the database. Files are read again when a page loads. Support asks for it.

To recreate one project:

  1. In the Projects pane, right-click the project.
  2. Choose Recreate project.
  3. Click Recreate in the dialog box.

Recreate database: the scope

With more than one project, Recreate asks for the Scope: Active project only or All N projects.

  • Active project only works like Recreate project on the active project. The other projects keep their data.
  • All N projects deletes the data of every project and reads them all again. This can take a long time.

Good to know

  • Your SOLIDWORKS files are never changed by these tools. Only the database is.
  • Stop process is safe during each of them. The files read so far are kept.
  • Close the documents in SOLIDWORKS before a recreate. A document with unsaved changes is read as it is saved on disk.
  • While a sync runs, a second one waits: "A sync is still running. Wait until it finishes, then try again."
  • After a Mvitec installer updated the Document Manager, run Recreate project once. See Files Saved with a Newer SOLIDWORKS.