Wrong Quantities

A quantity in the File Explorer or the BOM looks wrong? Mostly the cause is in the SOLIDWORKS files or in a setting. This page tells you how Vitreo counts and what to check.

How Vitreo counts

Vitreo counts the components of each assembly as they are saved on disk, in the configuration the parent uses. The total multiplies through every level: 2 frames with 4 brackets each give 8 brackets.

Vitreo does not count these components:

Component state in SOLIDWORKS Counted
Resolved or lightweight Yes
Suppressed No
Envelope No
Excluded from BOM No
Virtual (saved inside the assembly) No
Two active brackets and one suppressed: Qty 2, Qty (Sup) 1.

Tip Show the column Qty (Sup) in the BOM to see how many suppressed instances there are. Use the flat view filters to hide suppressed, envelope, virtual or excluded rows. See Flat View Filters.

Causes and what to do

You see Cause What to do
Parts of a subassembly are missing The subassembly is not on disk. See Files Need Attention. Put the file back or fix the reference.
A file is missing in the list Vitreo could not read it. See Files That Cannot Be Read.
A red row in the File Explorer The file is not found on disk. Put the file back, or fix the reference in SOLIDWORKS and save.
Quantities of the wrong configuration A configuration does not exist anymore, so another one is shown. Open the parent assembly, pick the right configuration and save.
A change in SOLIDWORKS does not show The assembly is not saved yet. Save the assembly in SOLIDWORKS. Vitreo reads the saved file.
Parts of a subassembly are not listed The subassembly is marked Order as one article. See Order as One Article.
One row instead of one per configuration, or the other way The setting Configurations as one item. See Configurations as One Item.
Only the top level or only parts The BOM type. See BOM Type.
Everything doubled The level 0 item has quantity 2 in the File Explorer. Adding the same item again raises its quantity. Type 1 in the quantity box of the level 0 row in the Hierarchical View.

Good to know

  • Always check the quantity in the flat view of the File Explorer. It shows the total of every file. See Flat View.
  • After a fix in SOLIDWORKS, save the file. Vitreo reads it again by itself. When the item boxes still look old, right-click the project and choose Recreate project.
  • Drawings are not counted.